| Use |
Specifications |
Series |
Data |
| ISDN Interface |
Adaptable to printed circuit board. |
G Series |
PDF HTML |
| Pulse transformer for data transmission |
Surface-mount type.
Dissipation rating: 150mW |
SG Series |
PDF HTML |
| Pulse transformer for data transmission |
Adaptable to printed circuit board. Dissipation rating: 150mW |
G Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Frequency range: 20Hz∼250kHz |
 |
| Use |
Specifications |
Series |
Data |
| Audio Transformers |
100Hz∼100kHz |
MG Series |
PDF HTML |
| Audio Inductors |
100Hz∼100kHz |
MG Series |
PDF HTML |
| Ultra Compact Audio Frequency Transformer |
400Hz∼250kHz |
MX Series |
PDF HTML |
| Audio Transformers |
200Hz∼20kHz |
DP Series |
PDF HTML |
| Transformers for mounting on P.C. Board |
30Hz∼20kHz |
Tp Series |
PDF HTML |
| Magnetic shield Transformers |
20Hz∼20kHz |
THs Series |
PDF HTML |
| Magnetic shield Transformers |
30Hz∼20kHz |
TPs Series |
PDF HTML |
| Lapping terminal type transformers |
30Hz∼20kHz |
TDP Series |
PDF HTML |
| |
30Hz∼20kHz |
TD Series |
PDF HTML |
| |
20Hz∼30kHz |
TK Series |
PDF HTML |
| |
30Hz∼20kHz |
TF Series |
PDF HTML |
| |
20Hz∼30kHz |
TN Series |
PDF HTML |
| |
40Hz∼15kHz |
A Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Frequency range: 300Hz∼10.0kHz |
 |
| Use |
Specifications |
Series |
Data |
| Telecommunication Transformers |
300Hz∼10.0kHz |
12T Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼10.0kHz |
14T Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼4.0kHz |
16T Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼4.0kHz |
19T Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼4.0kHz |
19Y Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼4.0kHz |
26Y Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼4.0kHz |
30Y Series |
PDF HTML |
| Telecommunication Transformers |
300Hz∼10.0kHz |
16L Series |
PDF HTML |
| Transformers for Modems |
200Hz∼4kHz |
12TM Series |
PDF HTML |
| Transformers for Modems |
200Hz∼4kHz |
14TM Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Use |
Specifications |
Series |
Data |
| Voice/Modem Line Transformer |
| V29,32,34,90,92Modem Voice Band |
SMD Molding |
TTC-50xx Series |
PDF |
| V29,32,34Modem Voice Band |
THD |
TTC-1xX,5xx,5xxx Series |
PDF |
| V29,32,34,90,92Modem Voice Band |
THD |
TTC-1xx,5xx,5xxx Series |
PDF |
| DAA Modem Transformer |
SMD Molding |
TTC-3xx Series |
PDF |
| xDSL Transfomer |
| ADSL |
SMD/THD |
TTC-4xxx Series |
PDF HTML |
| HDSL/HDSL2/SDSL/G.SHDSL |
SMD/THD |
TTC-4xxx Series |
PDF HTML |
| LAN & HomePNA |
| HOME PNA |
SMD |
TTC-2xxx Series |
PDF |
| LAN10Base-T |
SMD/THD |
TTC-8xxx Series |
PDF |
| LAN10/100Base-T |
SMD |
TTC-8xxx Series |
PDF |
| LAN Gigabit/1000Base-T |
SMD |
TTC-8xxx Series |
PDF |
| ISDN Transformers |
| T1 / E1 / CEPT / ISDN-PRI |
SMD/THD |
TTC-2xx,3xx,6xxx Series |
PDF HTML |
| T3/DS3/E3/STS-1 |
SMD |
TTC-3xx Series |
PDF HTML |
| ISDN BASIC INTERFACE |
SMD/THD |
TTC-7xxx Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Use |
Specifications |
Series |
Data |
| Hybrid Coils |
|
|
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Use |
Specifications |
Series |
Data |
| Ultra thin |
Adaptable to printed circuit board. |
LPP Series |
PDF HTML |
| Audio equipment, Medium / Large home electric appliances |
EI66∼114 size |
PEHM type |
PDF HTML |
| Audio equipment, Medium / Large home electric appliances |
EI76∼96 size |
PEAY type |
PDF HTML |
| Audio equipment, Medium / Large home electric appliances |
EI76∼96 size |
PEAT type |
PDF HTML |
| Audio equipment, Medium home electric appliances |
E148∼76 size |
PEHY type |
PDF HTML |
| Audio equipment, Medium / Large home electric appliances |
E148∼76 size |
PEHT type |
PDF HTML |
| Audio equipment, Small / Medium home electric appliances |
E135∼66 size |
PEPF type |
PDF HTML |
| Small home electric appliances for Stand-by Remote-control |
E128∼35 size |
PESB type |
PDF HTML |
| |
|
PEY,PEE type |
PDF |
| |
|
PEB type |
PDF |
| |
|
PMZF,PMZW type |
PDF |
| Three-phase Large Size Power Transformers |
0.85kVA∼28kVA(B type)1kVA∼35kVA(H type) |
GAT-T Series |
PDF HTML |
| Single phase Large Size Power Transformers |
2.8kVA∼8.8kVA(B type)3.3kVA∼11kVA(H type) |
GAT-S Series |
PDF HTML |
| Single phase Large Size Power Transformers |
300VA∼1.8kVA(B type)400VA∼2.3kVA(H type) |
PEOY Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Use |
Specifications |
Series |
Data |
| Reactor for power factor correction |
0.5mH∼82mH max 5A |
RLET type |
PDF HTML |
| Reactor for power factor correction |
0.5mH∼82mH max 7A |
RLEY type |
PDF HTML |
| Inverter air-conditioner, etc. |
|
PSR Series |
PDF |
| Harmonics Control Emission Control Reactor |
0.5mH∼82mH max 4.5A |
RS Series |
PDF HTML |
| Low leakage flux reactor for higher harmonic current inhibition |
|
RLEF,REY type |
PDF |
| Reactor |
high frequency range(∼30kHz level) |
SR Series |
PDF HTML |
| Reactor |
high frequency range(∼30kHz level) |
SE Series |
PDF HTML |
| Three-phase Reactor |
200A Max |
GAR Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |
 |
| Use |
Specifications |
Series |
Data |
| |
|
FA Series |
PDF |
| Barrier mold switching transformers |
3W∼180W (Flyback) |
SZ Series |
PDF |
| Switching transformer for DC-DC converter |
For surface mounting 1.8W∼17W |
DC Series |
PDF |
| Inverter transformer for back light |
Tube electric power: 1W∼5W |
CLF Series |
PDF |
| Common-mode choke coils |
|
CMF,CMF-H |
PDF HTML |
| Free Ajustable Separate Converter Transformer |
|
FASC Series |
PDF HTML |
|
 |
|
 |
 |
 |
 |



PC-8000 SERIES
Power supply transformers, using cut-cores, maching permalloy output transformers F-7000 series, The hight of the case is 121mm, which is designed to have the best balance with the dimention of output transformer fot a single ended application. Voltage setting is provided to meet various combination of almost all kinds of the vacuum tubes. |
| Primary Voltage |
Secondary Voltage,Current |
Catalogue No. |
Data |
| 0-95-100-105 |
400V-330V-0-330V-400V DC 200mA,
0-3.5V-6.3V-10V 3A, 5V 4A, 6.3V 3A |
PC-8001 |
PDF |
| 0-100 |
320V-280V-0-80V-280V-320V DC 200mA,
0-1V-2.3V 3A, 4V 3A, 0-2.5V-4V 5A, 2.5V 5A, 6.3V 3A |
PC-8002 |
| 0-100 |
400V-360V-0-120V-360V-400V DC 150mA, 5V 2A
0-4V-6.3V 2A, 0-4V-6.3V 2A, 0-5V-7.5V 2A, 0-4V-5V 2A |
PC-8003 |
|

PC-6000 SERIES
Power supply transformers, using cut-cores, matching amorphous output transformers F-5000 series. Voltage design is made for wide applications for use in combination with various kinds of vacuum tubes.
|
| Primary Voltage |
Secondary Voltage,Current |
Catalogue No. |
Data |
| 0-95-100-105 |
400V-330V-0-330V-400V DC 200mA,
0-3.5V-6.3V-10V 3A, 5V 4A, 6.3V 3A |
PC-6001 |
PDF |
| 0-100 |
320V-280V-0-80V-280V-320V DC 200mA,
0-1V-2.3V 3A, 4V 3A, 0-2.5V-4V 5A, 2.5V 5A, 6.3V 3A |
PC-6002 |
| 0-100 |
400V-360V-0-120V-360V-400V DC 150mA, 5V 2A
0-4V-6.3V 2A, 0-4V-6.3V 2A, 0-5V-7.5V 2A, 0-4V-5V 2A |
PC-6003 |
|

PC-3010 SERIES
Power supply transformers where cut cores are used.
Voltage design is made for wide applications for use in combination with various kinds of vacuum tubes.
|
| Primary Voltage |
Secondary Voltage,Current |
Catalogue No. |
Data |
| 0-100 |
450V-400V-350V-0 DC350mA, 70V DC30mA, 230V-180V-0 DC50mA,230V-180V-0 DC50mA
10V-6.3V-0 3.5A, 10V-6.3V-0 3.5A, 6.3V 1.5A |
PC-3011 |
PDF |
| 0-100 |
850V-0-850V DC200mA, 0-5V-10V 7A, 5V 4A,
6.3V 2.5A, 6.3V 2.5A, 340V-170V-0 DC80mA |
PC-3012 |
|

PC-3000 SERIES
Power supply transformers where cut cores are used.
Voltage design is made for wide applications for use in combination with various kinds of vacuum tubes.
|
| Primary Voltage |
Secondary Voltage,Current |
Catalogue No. |
Data |
| 0-100 |
320V-280V-0-80V-280V-320V DC200mA
2.3V-1V-0 3A, 4V 3A, 4V-2.5V-0 5A, 2.5V 5A, 6.3V 3A |
PC-3003 |
PDF |
| 0-100 |
400V-360V-0-120V-360V-400V DC250mA, 6.3V-4V-0 3.6A,
6.3V-4V-0 3.6A, 5V 3.8A, 5V-4V-0 3A, 7.5V-5V-0 3A |
PC-3004 |
| 0-100-110 |
330V-250V-0-80V-250V-330V DC250mA,
5V 3A, 6.3V 3A, 3.8V-1.3V-0 3A, 2.5V 3A |
PC-3005 |
| 0-100-110 |
400V-360V-0-80V-360V-400V DC300mA
5V 3A, 6.3V 3A, 6.3V 4A |
PC-3007 |
|



F-7000 SERIES
This has been developed and manufacturerd with an aim to improve a tone quality from low zone to high zone, using the permalloy core (Nickel content approx.38%, special order by Tamura), including output transformer which uses permalloy core for 3-pole tube single exclusive use, and output transformer for push-pull. The products have been completed to contribute to improve customers' sound life, carefully selecting a tone quality which is indispensable for output transformer. Having sufficient output capacity and volume of information, the customers will hopefully enjoy an excellent wide zone sound through various feelings such as voluminous low and high zones, also expansion of sound and profound vivid presentation. Entire satisfaction will be covered without feeling of an existence of the analog and digital source.
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Primary Inductance
(H) |
Catalogue No. |
Data |
| Primary |
Secondary |
Balance |
Unbalance |
| 3K (Single) |
0-4-8-16 |
15∼60K |
8 |
100 |
20 |
F-7001 |
PDF |
| 3.5K (Single) |
0-4-8-16 |
15∼50K |
10 |
100 |
25 |
F-7002 |
| 5K (Single) |
0-4-8-16 |
15∼50K |
10 |
100 |
30 |
F-7003 |
| 7K (Single) |
0-4-8-16 |
15∼30K |
5 |
50 |
25 |
F-7004 |
| 3.5K (Push) |
0-4-8-16 |
20∼80K |
70 |
150×2 |
10 |
100 |
F-7020 |
| 5K (Push) |
0-4-8-16 |
20∼80K |
70 |
150×2 |
10 |
200 |
F-7021 |
|

F-5000 SERIES
Applications can be found in various wide range circuits, in combination with output transformers for vacuum tubes where new material amorphous (amorphous alloy) is used, 5-pole tubes, 3-pole tubes and many other kinds of vacuum tubes. It creates a new sound world with a profound depth and expanse.
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Primary Inductance
(H) |
Catalogue No. |
Data |
| Primary |
Secondary |
Balance |
Unbalance |
DC 0mA |
DC 10mA |
| 3K (Single) |
0-4-8-16 |
10∼100K |
8 |
100 |
- |
18 (100mA) |
F-5002 |
PDF |
| 5K (Single) |
0-4-8-16 |
10∼100K |
8 |
100 |
- |
20 (100mA) |
F-5003 |
| 7K (Single) |
0-8-16 |
10∼80K |
8 |
100 |
- |
23 (100mA) |
F-5004 |
| 3.5K (Push) |
0-4-8-16 |
10∼100K |
42 |
120×2 |
10 |
100 |
70 |
F-5005 |
| 5K (Push) |
0-4-8-16 |
10∼100K |
42 |
120×2 |
10 |
160 |
80 |
F-5006 |
|

F-2020 SERIES
Output transformers for push-pull exclusive use for output 50W. In combination with various kinds of vacuum tubes including 5-pole tubes and 3-pole tubes, these can be used in many different circuits.
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Primary Inductance
(H) |
Catalogue No. |
Data |
| Primary |
Secondary |
Balance |
Unbalance |
DC 0mA |
DC 10mA |
3.5K P-P with UL tap |
0-4-8-16 Cathode NFB winding |
10∼100K |
50 |
150×2 |
10 |
90 |
60 |
F-2020 |
PDF |
5K P-P with UL tap |
0-4-8-16
Cathode NFB winding |
10∼80K |
50 |
130×2 |
10 |
150 |
70 |
F-2021 |
|

F-2010 SERIES
Output 100W push-pull exclusive use output transformer which can be used in combination with 5-pole tubes, 3-pole tubes and many other kinds of vacuum tubes in various circuits. (F-2011, 2012)
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Primary Inductance (H) |
Catalogue No. |
Data |
| Primary |
Secondary |
Balance |
Unbalance |
DC 0mA |
DC 10mA |
3.5K P-P with UL tap |
0-4-8-16
Cathode NFB winding |
5∼100K |
100 |
200×2 |
5 |
110 |
80 |
F-2011 |
PDF |
5K P-P with UL tap |
0-4-8-16 Cathode NFB winding |
5∼80K |
100 |
180×2 |
5 |
210 |
150 |
F-2012 |
| 10K (Single) |
0-4-8-16 |
20∼50K |
40 |
100 |
50 (100mA) |
F-2013 |
|

F-2000 SERIES
Output transformers for 3-pole tubes exclusive use, marking a constant loss 0.25dB value for first time for the output transformers. This fact was due to our attempt to have good selection of iron core, sufficient margin for output capacity, and a success to reduce the primary winding resistance to below 1/5 of the traditional level. Further, satisfactory results were obtained for the frequency, phase characteristics which were factors of inverse proportion.
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Primary Inductance (H) |
Catalogue No. |
Data |
| Primary |
Secondary |
| 3.5K |
0-8-16 |
30∼100K |
8 |
100 |
13 |
F-2003 |
PDF |
| 5K |
0-8-16 |
30∼80K |
8 |
100 |
16 |
F-2004 |
| 7K |
0-8-16 |
30∼70K |
8 |
100 |
21 |
F-2005 |
| 2K |
0-4-8-16 |
10∼60K |
10 |
100 |
17 |
F-2006 |
| 3K |
0-4-8-16 |
10∼60K |
10 |
100 |
25 |
F-2007 |
|

F-400, 600, 700 SERIES
Wide band output transformers with third winding for NFB exclusive use, which can make stabilized NFB circuit, eliminating unstable oscillation through the changes of secondary load. Impedance for NFB winding is 16Ω. SG taps are provided for the models excepting F781, 782, 783, so that UL circuits can be constructed.
|
| Impedance |
Frequency Range (Hz) |
Output (W) |
Primary MAX. DC Current (mA) |
Remarks |
Catalogue No. |
Data |
| Primary |
Secondary |
Balance |
Unbalance |
| 5K (Single) |
0-4-8-16 |
30∼50K |
7.5 |
45 |
6V6, 6BQ, 5, 6RP15 etc. |
F-475 |
PDF |
| 5K (Push) |
0-4-8-16 |
30∼50K |
15 |
110×2 |
10 |
2A3, 6L6, 5, 6RP15 etc. |
F-483 |
| 8K (Push) |
0-4-8-16 |
30∼50K |
15 |
110×2 |
10 |
6V6, 6AQ5, 6BQ5 etc. |
F-485 |
| 10K (Push) |
0-4-8-16 |
30∼50K |
15 |
110×2 |
10 |
6V6, 6AQ5, 6AR5 etc. |
F-486 |
| 3.5K (Push) |
0-4-8-16 |
30∼50K |
30 |
200×2 |
20 |
2A3, 6CA7, 6GB8 etc. |
F-682 |
| 5K (Push) |
0-4-8-16 |
30∼50K |
30 |
150×2 |
10 |
2A3, 6L6, 6CA7 etc. |
F-683 |
| 6.6K (Push) |
0-4-8-16 |
30∼50K |
30 |
150×2 |
10 |
6L6, KT66, 6CA7 etc. |
F-684 |
| 8K (Push) |
0-4-8-16 |
30∼50K |
30 |
150×2 |
10 |
6L6, 6GB8, 6CA7 etc. |
F-685 |
| 2.5K (Push) |
0-4-8-16-32 |
30∼50K |
50 |
250×2 |
20 |
6GB8, Parallel, 2A3, 6L6 etc. |
F-781 |
| 3.8K (Push) |
0-4-8-16-32 |
30∼50K |
50 |
250×2 |
20 |
6L6, 6CA7, 6550 etc. |
F-782 |
| 5K (Push) |
0-4-8-16-32 |
30∼50K |
50 |
250×2 |
20 |
6L6, 6CA7, 6GB8 etc. |
F-783 |
|



A-4005, 4006
Power inductors matching with new design amorphous output transformers F-5000 series, and inductance value and current capacity can be separately usable in 2 ways due to 2-wire winding system. Inductance value is stabilized toward current variation which are usable easily for overcurrent within 20% level.
|
| Inductance (H) |
DC Current (mA) |
DC Resistance(Ω) |
Catalogue No. |
Data |
| Series Conntn. |
Parallel Current |
Series Conntn. |
Parallel Current |
Series Conntn. |
Parallel Current |
| 5 |
1.25 |
250 |
500 |
80 |
20 |
A-4005 |
PDF |
| 10 |
2.5 |
200 |
400 |
140 |
35 |
A-4006 |
|

A-4003, 4004
2-winding system power inductor, which can be seprately used in 2-ways for inductance value and current capacity. Inductance value is stabilized for current variation and can be used in stable from for overcurrent within 20% level.
|
| Inductance (H) |
DC Current (mA) |
DC Resistance (Ω) |
Catalogue No. |
Data |
| Series Conntn. |
Parallel Current |
Series Conntn. |
Parallel Current |
Series Conntn. |
Parallel Current |
| 5 |
1.25 |
250 |
500 |
65 |
16 |
A-4003 |
PDF |
| 10 |
2.5 |
200 |
400 |
120 |
30 |
A-4004 |
|

A-300 SERIES
Inductance variation is becoming smaller against current variation. Inductance variation can scarcely be seen against variation within 20%. *Please keep in mind that the plate of brand name "TAMRADIO" will not come with the A-300 series products.
|
| Inductance (H) |
Series Conntn. (mA) |
DC Resistance (Ω) |
Catalogue No. |
Data |
| 100 |
10 |
2000 |
A-393 |
PDF |
| 30 |
40 |
740 |
A-394 |
| 10 |
120 |
110 |
A-395 |
| 5 |
200 |
70 |
A-396 |
|



B-6000 SERIES
Interstage driver transformers which match with new design amorphous output transformers F-5000 series, having various impedances meeting with various vacuum tubes, also can be used at DC superposition.
|
| Impedance |
Frequency Range (Hz) |
Output (dBm) |
Winding
Ratio |
Primary MAX. DC Current (mA) |
Catalogue No. |
Data |
| Primary |
Secondary |
| 10K |
40Kpp |
30∼15K |
25 |
1:2 |
10 |
B-6001 |
PDF |
| 10K |
40K |
30∼15K |
25 |
1:2 |
10 |
B-6002 |
| 5K |
20Kpp |
30∼15K |
25 |
1:2 |
30 |
B-6003 |
| 5K |
20K |
30∼15K |
25 |
1:2 |
10 |
B-6004 |
| 20Kpp |
20Kpp |
30∼15K |
25 |
1:1 |
20×2 |
B-6005 |
| 10Kpp |
40Kpp |
30∼15K |
25 |
1:2 |
20×2 |
B-6006 |
| 10Kpp |
10Kpp |
30∼15K |
25 |
1:1 |
40×2 |
B-6007 |
| 5Kpp |
20Kpp |
30∼15K |
25 |
1:2 |
40×2 |
B-6008 |
|

B-5000 SERIES
The Interstage Driver Transformers which match with all types of output transformers. can meet with various impedance of various vacuum tubes, and also can be used at DC superposition.
|
| Impedance |
Frequency Range (Hz) |
Output (dBm) |
Winding
Ratio |
Primary MAX. DC Current (mA) |
Catalogue No. |
Data |
| Primary |
Secondary |
| 10K |
40Kpp |
30∼15K |
25 |
1:2 |
10 |
B-5001 |
PDF |
| 10K |
40K |
30∼15K |
25 |
1:2 |
10 |
B-5002 |
| 5K |
20Kpp |
30∼15K |
25 |
1:2 |
30 |
B-5003 |
| 5K |
20K |
30∼15K |
25 |
1:2 |
10 |
B-5004 |
| 20Kpp |
20Kpp |
30∼15K |
25 |
1:1 |
20×2 |
B-5005 |
| 10Kpp |
40Kpp |
30∼15K |
25 |
1:2 |
20×2 |
B-5006 |
| 10Kpp |
10Kpp |
30∼15K |
25 |
1:1 |
40×2 |
B-5007 |
| 5Kpp |
20Kpp |
30∼15K |
25 |
1:2 |
40×2 |
B-5008 |
|
 |
|
 |
 |

|